DALTU Door Commercial · Worldwide
The secure door for buildings that can't afford to guess.
Brushed stainless, eight locking points, biometric and PIV access, wired only. Built for government offices, data centers and laboratories, and engineered toward UL 752 Level 8.

- 8Locking points: lock edge, head and hinge side
- L8UL 752 Level 8 design target, in testing
- 0Radios. No Wi-Fi, Bluetooth or NFC
- 90 minFire-rated option, UL 10C target

01 · The outside face
Flat stainless. No handle, no keypad, no visible hinge.
From the corridor you see a single sheet of brushed 304 stainless, the DALTU mark, a black sensor strip in the head and a thin access column in the frame. No exposed handle, hardware or hinge to work on.
- Leaf
- Brushed 304 stainless, laser-engraved mark
- Access column
- In the lock jamb, about 22 mm wide
- Credentials
- Iris and 3D face. PIV/CAC card mode, off by default.
02 · Locking
Eight steel bolts on three sides. Two motorized hinges.
Three bolts on the lock edge, two in the head and three dog bolts on the hinge side. Four heavy hinges carry the leaf; the top and bottom are DALTU motorized hinges that open and close the door on command.
- Locking points
- 3 lock edge · 2 head · 3 hinge-side dog bolts
- Hinges
- 4 heavy hinges, 2 motorized
- Attack rating
- UL 752 Level 8 design targetIn testing


03 · The brain
Wired, radio-silent and ready for your access control system.
PoE++
One cable
Power and data over a single PoE++ run. No batteries to service, no wireless to jam.
OSDP
Speaks your system
Connects to existing access control panels over OSDP, with a fire alarm input on board.
FIPS 140-3
Keys stay in hardware
Credentials and keys are held in a secure element designed to FIPS 140-3 Level 3.
04 · Life safety
Locked from outside. One turn of the lever to leave, even without power.
From the inside the lever always opens the door, with or without power, at an ADA-compliant force. The fire-rated version uses the DALTU drive as its closer and adds a Fire Service Panel and a stair re-entry kit.
- Egress
- Mechanical lever, no power needed, ADA force
- Fire option (FR)
- 90 minutes, UL 10C targetIn testing
- Fire service
- Fire Service Panel and stair re-entry kit

05 · Where it goes
Government offices, data centers and laboratories.



06 · Specifications
Two versions, five sizes.
- 914 × 2134 mm · 3070 standard
- 1067 × 2134 · 3670
- 1219 × 2134 · 4070
- 914 × 2438 · 3080
- 1067 × 2438 · 3680
Leaf sizes shown in millimetres and US nominal sizes. Other sizes on request.
- BR8
- Attack-resistant, UL 752 Level 8 target
- FR
- Fire-rated, 90 min, UL 10C target
- Finish
- Brushed 304 stainless
- Access
- Iris · 3D face · PIV/CAC (optional)
- Connectivity
- PoE++ · OSDP · wired only
- Standards
- Tested to UL in the US. Other national standards on request
- Delivery
- Worldwide, through the DALTU Team
- Status
- Prototype stage. Listings in progress; pricing on request.
07 · Talk to us
Request a briefing.
Tell us about the building and the openings. The DALTU Team will come back with drawings, a test schedule and a quote.
